  • Page 1: User Manual

    KBU64 Rackmount User Manual Fivemere Ltd. Fivemere House 161 High Street Aldershot Hampshire, England GU11 1TT Cabletron Systems Ltd. Network House Newbury Business Park London Road, Newbury Berkshire, England RG13 2PZ Telephone: [44] (0)1635 580000 Fax: [44] (0)1635 44578...
  • Page 2 European O.J. All testing was carried out using screened interconnection cables. Should the equipment be used in a different environment the user may need to take additional EMC precautions. Acknowledgements: Kilostream™ is a trademark of British Telecom PLC. Fivemere Ltd. is a subsidiary of Cabletron Systems Inc., USA. 80-10100001-09...
  • Page 3 History Sheet 80-10100001-09 Issued separately for the R/M due to USA requirements 80-10100001-09 KBU64 Rackmount User Manual 21 January 1998...
  • Page 4: Table Of Contents

    KBU64 Rackmount User Manual TABLE OF CONTENTS KBU 64 RACKMOUNT SPECIFICATION NTRODUCTION FRONT AND REAR PANELS AND INTERFACES RONT ANEL NTERFACE ARDS 2.2.1 ETTINGS 2.2.2 - KBU 64 R OMMAND 2.2.3 V35 R NTERFACE 2.2.4 X21 R NTERFACE 2.2.5 V24 R...
  • Page 5: Kbu 64 Rackmount Specification

    KBU 64 Rackmount Specification 1.1 Introduction This manual describes the Rackmount version of the KBU64. standalone KBU 64 has its own manual, Publication 80-10100000. For information on the command menus and parameters in the rackmount version, you will need to refer to the standalone KBU 64 manual. The rackmount KBU 64 is a dual channel rack mountable card that uses the KBU 64 Card Frame as a host for power and management via the Management Card.
  • Page 6 KBU64 Rackmount User Manual Fivemere Figure 1.1 The KBU 64 Rackmount Version Up to 13 KBU 64 card pairs may be fitted with either one or two power supplies for resilience. The 1st card slot is for the Manager Card which controls all cards within the rack via the KBU 64 polled management system.
  • Page 7 The rackmount version of the KBU 64 is functionally the same as the standalone in most respects, as it uses the same software. Therefore most of the sections of your KBU64 Manual manual (Publication 80- 10100000) relating to KBU 64's operation are relevant. The rackmount card functionality differs in the following ways:- There is a single 15 way command port on each KBU 64 rear card for all commands and alarms.
  • Page 8: Front And Rear Panels And Interfaces

    Front and Rear Panels and Interfaces 2.1 Front Panel See the KBU64 standalone manual (Publication 80-10100000) for the description of operation. 2.2 Rear Interface Cards With all 3 card types the USER ports are configured as physical DCEs, the LINK ports as DTEs. The USER ports are female and the LINK are male for X21 and V24, both USER and LINK ports are female for V35.
  • Page 9 KBU64 Rackmount User Manual U S E R 1 T 1 0 3 R 1 0 4 C 1 0 8 I 1 0 7 S 1 1 4 1 1 5 1 0 5 1 0 9 B A C K U P...
  • Page 10: Link Settings

    2.2.1 Link Settings For all 3 types of Rear Interface Card the command port jumper settings are as follows: Without Manager Card Link Normal JP10 JP11 JP12 JP13 JP14 'X' = don't care 80-10100001-09 Front and Rear Panels and Interfaces Polled Polled Only With...
  • Page 11: Command Port - Kbu 64 Rear Interface Cards

    KBU64 Rackmount User Manual 2.2.2 Command Port - KBU 64 Rear Interface Cards The command port on each of the Rear Interface Card types is a female 15 way 'D' type and uses the same V28 level circuits as the standalone KBU 64.
  • Page 12: V35 Rear Interface Card

    2.2.3 V35 Rear Interface Card The User and Link connectors are both 34 way female MRAC. The pin assignments are as follows: Circuit Signal Name Chassis Earth Signal Ground/Chassis Earth 103A Transmit Data A 103B Transmit Data B 104A Receive Data A 104B Receive Data B Request to Send...
  • Page 13: X21 Rear Interface Card

    KBU64 Rackmount User Manual 2.2.4 X21 Rear Interface Card The User and Link connectors are both 15 way 'D'. The pin assignments are as follows: Circuit Signal Name Ground Chassis Earth Signal Ground/Chassis Earth Transmit Data A Transmit Data B...
  • Page 14: Manager Card

    3.1 Introduction The KBU 64 Manager Card is a discrete card for use with only rackmount KBU 64 cards. Like the rackmount KBU 64, the Manager Card also consists of a card pair. The rear card provides a command port for management of all KBU 64 cards within its rack. The Manager Card must always be fitted in slot 1, the slot on the left when viewing the rack from the front.
  • Page 15 KBU64 Rackmount User Manual R X D TX D P W R 1 P W R 2 F ro n t Figure 3.1 Front and Rear Panels of the Manager Card 3–2 O F F O F F O F F...
  • Page 16: Front Panel

    3.2 Front Panel The front panel of the Manager Card has the following controls and indicators: Transmit and receive data LED’s for the command terminal data lines. These LED’s display data activity on both the transmit and receive data circuits. AC power indication for each of the power supplies.
  • Page 17 KBU64 Rackmount User Manual The pin assignments are as follows: Pin No. Circuit No. These command ports are PSV4/1 compatible and can therefore be connected to external port sharing devices (PSV’s) for management of multiple racks of KBU 64s in the same way as the standalone version.
  • Page 18: Card Installation

    Each KBU 64 ‘front’ card must be associated with an appropriate (V.24, X.21, or V.35) rear interface card i.e. they should always be installed in pairs (although no damage will result in partial installation) If the KBU 64s are to be managed individually via their rear panel command port and there is no manager card present then, after connection of the user, link, and command cables, the KBU 64s can be treated in the same manner as standalone KBU 64s for configuration...
  • Page 19: Configuration Using A Manager Card

    KBU64 Rackmount User Manual 4.2 Configuration Using a Manager Card With the Manager Card pair and all KBU card pairs fitted the first task is to set the individual KBU 64 poll numbers. Once all the units are installed and a suitable terminal connected to the rack manager card...
  • Page 20: Installation And Power Supply Requirements

    Installation and Power Supply Requirements Installation and Power Supply Requirements Safety Before connecting the mains supply to the Warning: unit check the supply voltage as detailed below. The product is a high density rack mounted unit designed to sit in a 19" communications cabinet, it has four fixing points, two down each side of the front of the frame.
  • Page 21 KBU64 Rackmount User Manual should be removed and the cable re-wired to the correct type of plug. The use of adaptors is not recommended. The wires in the supply cord are coloured in accordance with the following code:- Green and Yellow Earth...
  • Page 22 Installation and Power Supply Requirements 20mm x 5mm, 3.15AH,250V Anti-surge (T) type for 110V to 120V ratings. If any problems are encountered with fuses continually blowing the following alternative ratings maybe used: 20mm x 5mm, 3.15AH,250V Anti-surge (T) type for 220V to 240V ratings.
  • Page 23: Rack Specifications

    Rack Specifications Dimensions Mains Voltage Consumption Frequency Mains Rear Panel Fuses 80-10100001-09 Rack Specifications 482mm W; 400mm H (9U); 370mm D 93-132V (110-120V nominal) 187-264V (220-240V nominal) 200VA max. 50/60Hz nominal 1.6 or 3.15AH, 250V Anti-Surge (T) 20x5mm (220-240V range) 3.15 or 6.3AH, 250V Anti-Surge (T) 20x5mm (110-120V range) 6–1...
  • Page 24 KBU64 Rackmount User Manual Environment 6–2 Ambient temperature: Operating 0 C to 30 C Storage -20 C to 70 C Atmospheric pressure: 86.0kPa to 106.0kPa Relative Humidity: 5% to 95% non-condensing 80-10100001-09...
  • Page 25: Regulatory Requirements

    Regulatory Requirements 7.1 United Kingdom and Europe Users based in the United Kingdom and Europe must pay particular attention to the information contained in sections B.A.B.T. Pan European Approval number AA6046512. 1. The KBU 64 Rackmount is approved for connection to ISDN and X.21 leased circuit services...
  • Page 26 KBU64 Rackmount User Manual 3. The KBU 64 Rackmount is approved for direct connection to the X.21 and X.21 bis (V.35) or X.21 bis (V.28) Kilostream Telecom PLC or any similar service provided by other British Telecommunications operators, or a relevant branch system for those digital circuits which accord to CCITT recommendations X.21 and X.21...