Changing The Com Port Application - Cabletron Systems 2H28-08R User Manual

Cabletron systems, inc. user's guide smartswitch 2h28-08r
Hide thumbs Also See for 2H28-08R:
Table of Contents

Advertisement

5.
When the message "SAVED OK" appears, the edits are saved.
Exiting without saving causes the message "NOT SAVED --
NOTE
PRESS SAVE TO KEEP CHANGES" to display. Exiting without
saving causes all edits to be lost.

5.7.10.1 Changing the COM Port Application

After enabling the COM port as described in
select one of the applications supported by the COM port: LM or UPS.
The default application is LM.
To change the COM port application:
1.
Use the arrows keys to highlight the Application field.
2.
Use the SPACE bar or BACKSPACE to toggle the available settings
until the operation you require appears.
settings and their corresponding applications.
Setting
LM
UPS
3.
Press ENTER to accept the application.
4.
Use the arrow keys to highlight the SAVE command at the bottom of
the screen, then press the ENTER key.
5.
When the message "SAVED OK" displays, the edits are saved.
When the COM port is configured to perform the UPS
!
application, all future Local Management connections must be
CAUTION
made by establishing a Telnet connection to the device. Ensure
that the device has a valid IP address before saving changes to
the COM port application. If the module does not have a valid
IP address and the changes are saved, refer to
instructions on clearing NVRAM in order to reestablish COM
port communications.
2H28-08R SmartSwitch 2208 User's Guide
Table 5-3 COM Port Application Settings
Application
Local Management Session
APC Power Supply SNMP Proxy
General Configuration Screen
Section
5.7.10, you can
Table 5-3
lists the available
Appendix C
for
5-29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartswitch 2208Smartswitch 2208 2h28-08r

Table of Contents

Save PDF