Environmental Requirements; A.4 Environmental Requirements; Input/Output Ports; Com Pinout Assignments - Cabletron Systems 2E43-51 User Manual

Cabletron systems user's guide smartswitch 2e43-51, 2e43-51r
Table of Contents

Advertisement

Appendix A: Specifications
A.4

ENVIRONMENTAL REQUIREMENTS

Operating Temperature:
Storage Temperature:
Operating Relative Humidity:
A.5

INPUT/OUTPUT PORTS

ENET 1 through ENET 4
(ports 1 through 4):
Slots for optional Fast Ethernet
Interface Modules
(ports 5 and 6):
Slot for optional HSIM:
A.6

COM PINOUT ASSIGNMENTS

The COM port is a serial communications port that supports Local
Management or connection to a UPS.
Table A-1
shows the COM port pin assignments.
Pin
Signal Name
1
Transmit Data (XMT)
2
Data Carrier Detect (DCD)
3
Data Set Ready (DSR)
4
Receive Data (RCV)
5
Signal Ground (GND)
6
Data Terminal Ready (DTR)
7
Request to Send (RTS)
8
Clear to Send (CTS)
A-2
5°C to 40°C (41°F to 104°F)
-30°C to 73°C (-22°F to 164°F)
5% to 90% (non-condensing)
Ethernet (10BASE-T compliant) with
RJ21 type connectors. Each connector
provides connection for 12 twisted pair
ports.
Slots accept three types of optional Fast
Ethernet Interface Modules:
FE100-TX, FE100-FX, and FE100-F3.
Slot accepts optional High Speed
Interface Modules.
Table A-1 COM Port Pin Assignments
Input/Output
Output
Output
Input
Input
NA
Output
Input
NA
2E43-51/2E43-51R User's Guide