The following section defines the fields on the Repeater Level Security
Configuration screen.
Interface (Read-Only)
Indicates the repeater port on the ENET connector (ENET 1 through 4)
selected in the Interface field. Refer to
port relationship on the device.
ENET 1 = Repeater ports 1 – 12
ENET 2 = Repeater ports 13 – 24
State (Selectable)
Used to select the state of security for frames received by any port on the
connector. The states are as follows:
Secure – Allows the ports on the connector to receive only those
frames with the address as determined by the selection in the
Lock/Learn field.
NonSecure – Allows the ports on the connector to receive all frames.
The source address of received frames is not examined and the frames
are processed in a non secure state.
Lock/Learn (Selectable)
Used to select the type of security for frames received by any port on the
connector. The security types are as follows:
LockOnNext – The next frame received by each port is examined to
learn its source address. As the source address of a frame is learned on
a port, only those frames received with that same source address are
processed on that port. Any other address detected is considered as an
intruder and the device executes the actions selected in the Action On
Intruder field.
2E43-51/2E43-51R User's Guide
Table 5-4 ENET/Repeater Port Relationship
Repeater Level Security Configuration
Table 5-4
ENET 3 = Repeater ports 25 – 36
ENET 4 = Repeater ports 37 – 48
for the ENET/repeater
5-63