Cabletron Systems 2E43-51 User Manual page 157

Cabletron systems user's guide smartswitch 2e43-51, 2e43-51r
Table of Contents

Advertisement

TOP VIEW WITHOUT COVER
Primary
Power
Supply
Flash
DRAM
Figure C-2 2E43-51 Mode Switch Location/Component Layout
Switch definitions and positions are as follows:
Switches 1 through 4 – For Cabletron Systems use only.
Switch 5 – COM Port Autobaud. The default (OFF) position enables
Autobaud sensing on the COM port for Local Management sessions.
Changing the switch to the ON position disables Autobaud sensing and
sets the COM port to 9600 baud for Local Management sessions.
Switch 6 – Forced BootP. Do NOT attempt a Forced BootP unless a
BootP server has been configured for the 2E43-51. The BootP server
references the location of a station acting as a Trivial File Transfer
Protocol (TFTP) server containing the 2E43-51 image file. When the
position of Switch 6 is changed and the power is cycled to the
2E43-51, the device requests the image file location from the BootP
server and uses TFTP to download the image from the TFTP server. If
one of these requirements is not met, the 2E43-51 will continue to
request either the BootP server or the TFTP server until the RESET
button on the 2E43-51 is pressed. Once the RESET button is pressed,
the 2E43-51 will reset after one minute and load the image stored in
FLASH memory.
2E43-51/2E43-51R User's Guide
Redundant
Power
Supply
(2E43-51R
only)
FRONT PANEL
Removing the Chassis Cover
MODE SWITCH BANK
8
7
6
5
4
3
2
1
OFF
ON
2251-05
C-5