40 Troubleshooting
Troubleshooting of electrical system (E-mode)
No.
Cause
Ground fault in wiring
harness
10
(Contact with ground
circuit)
Defective machine
11
monitor
40-390
Procedure, measuring location, criteria, and remarks
If no failure is found by checks on causes 3 to 5 and 7, this check is not
required.
1. Turn starting switch to OFF position, and turn battery disconnect switch to
OFF position.
2. Disconnect fusible link F03, No. 15 and No. 17 terminals of fusebox F01,
and connectors H15, CM01, and CP01.
3. Connect T-adapters to male side of connector F03 and female side of H15
and CM01.
Between ground and battery (+) or F03 (male) (1)
Between ground and F03 (male) (2) or F01-16F
Between ground and F01-17, CM01 (female) (1),
Resistance
(2), or H15 (female) (1)
Between ground and H15 (female) (5) or CM01
(female) (10)
If no failure is found by preceding checks, machine monitor is defective.
(Since this is an internal defect, troubleshooting cannot be performed.)
Min. 1 Mz
Min. 1 Mz
Min. 1 Mz
Min. 1 Mz