30 Testing and adjusting
Electrical system
Testing (Reset Number of Abrupt Engine Stop
by AIS)
(PC88MR-AF87-360-K-00-A)
On the machine monitor, the cylinder cutout mode
operation and reset of sudden stop numbers can be
executed.
Reset number of abrupt stops by auto idle stop is
used to reset the counter that counts the high
engine speed status when stopping the engine by
the auto idle stop function memorized in the
machine. The reset is performed after replacing the
turbocharger.
1. Selecting a menu
Select the "Diagnostic Tests" on the "Service
Menu" screen.
2. Selecting a sub menu
After the "Diagnostic Tests" screen is displayed,
select "Reset Number of Abrupt Engine Stop by
AIS" using the function switch or numeral input
switches.
a Selecting method is the same as on the
"Service Menu" screen.
3. Setting selectable time
After the "Reset Number of Abrupt Engine Stop
by AIS" screen is displayed, select a setting by
using the function switch.
[F5]: Returns to the "Diagnostic Tests"
screen
[F6]: Executes reset
30-114
a Perform the sudden stop number reset after
replacing the turbocharger.
Adjustment (Pump Absorption
Torque)
(PC88MR-C201-27E-K-00-A)
You can perform various adjustments related to the
machine with the machine monitor.
The sub menu of Pump Absorption Torque is used
to finely adjust the absorption torque of the
hydraulic pump.
1. Selecting menu
Select "Adjustment" on the "Service Menu"
screen.
2. Selecting sub menu
After the "Adjustment" screen is displayed,
select "Pump Absorption Torque" by using the
function switch or numeral input switches.
a Selecting method is the same as on the
"Service Menu" screen.