Komatsu PC88MR-10 Shop Manual page 1343

Hydraulic excavator
Hide thumbs Also See for PC88MR-10:
Table of Contents

Advertisement

Receiver drier
(PC400-K5E2-041-K-00-A)
A: Refrigerant inlet (from condenser)
B: Refrigerant outlet (to air conditioner unit)
Function
(PC400-K5E2-042-K-00-A)
The receiver drier temporarily stores the high pressure and high temperature liquid refrigerant from the
condenser so that it can be supplied to the evaporator according to the need of cooling.
It sends the stored refrigerant from its bottom to the evaporator, allowing the refrigerant to be liquefied
completely ever when it contains bubbles due to the lower heat dissipation of the condenser.
The built-in filter and desiccating agent eliminate foreign substances in the circulation circuit and water
content in the refrigerant.
Specification
(PC400-K5E2-044-K-00-A)
Effective volume (cc)
Weight of desiccating agent (g)
PC88MR-10
80 Appendix
Condenser
370
290
80-19

Advertisement

Table of Contents
loading