a The following items can be selected on the
"Maintenance Mode Setting" screen.
"00 Maintenance Mode Change"
"49 Air Cleaner Cleaning or Change Interval"
"60 Coolant Change Interval"
"41 Fuel Prefilter Change Interval"
"01 Engine Oil Change Interval"
"02 Engine Oil Filter Change Interval"
"05 Hydraulic Oil Tank Breather Change Interval"
"03 Fuel Oil Tank Breather Change Interval"
"04 Hydraulic Oil Filter Change Interval"
"07 Damper Case Oil Check or Refilling Interval"
"09 Swing Machinery Case Oil Change Interval"
"08 Final Drive Case Oil Change Interval"
"10 Hydraulic Oil Change Interval"
"99 All Default Value"
3. Setting of maintenance mode change
After selecting "Maintenance Mode Change"
and the screen is displayed, select the desired
setting by using the function switches.
ON: All of functions of maintenance items
become effective in operator mode.
OFF: All of functions of maintenance items
becomes ineffective in operator mode.
[F3]: Moves selection downward
[F4]: Moves selection upward
[F5] Cancels selection and returns to the
"Maintenance Mode Change" screen
[F6]: Enters selection and returns to
"Maintenance Mode Change" screen
a Even if ON/OFF of each item has been set, if
the above setting is changed, it overrides the
individual setting.
PC88MR-10
30 Testing and adjusting
4. Setting of Maintenance Notice Time Setting
After
selecting
"Maintenance
Setting", if the screen is displayed, set with the
function switches.
Default value: Maintenance notice time set
on the machine monitor (Recommended by
the manufacturer and not changeable).
Set value: Maintenance time that can be
freely set. Maintenance reminder function
works according to this set time in operator
mode (the time increases or decreases in
multiples of 10 hours).
[F3]: Decreases set value
[F4]: Increases set value
[F5]: Cancels contents of setting before entry
and returns to the "Maintenance Mode
Change" screen
[F6]: Enters setting and returns to
Maintenance mode setting screen
Electrical system
Notice
Time
30-105

Advertisement

Table of Contents
loading

Table of Contents