Komatsu PC88MR-10 Shop Manual page 484

Hydraulic excavator
Hide thumbs Also See for PC88MR-10:
Table of Contents

Advertisement

30 Testing and adjusting
Pm clinic
Machine model
Testing conditions
Item
Hydraulic oil temperature: 45 to
55°C
Engine: High idle
Working mode: P mode
Measurement range: Between
bucket CURL stroke end and
Bucket
bucket DUMP stroke end
DUMP
Measurement posture:
Horizontal boom top face (See
chapter 20, "Work equipment 4"
in "Machine posture and
procedure for measuring
performance".)
Hydraulic oil temperature: 45 to
55°C
Engine: High idle
Working mode: P mode
Boom
Measurement range: Between
swing
LEFT stroke end and RIGHT
stroke end
LEFT o
Measurement posture: See
RIGHT
chapter 20, "Work equipment 5"
in "Machine posture and
procedure for measuring
performance".
30-134
Engine
PC88MR-10
SAA4D95LE-6
Standard
Repair limit
Unit
value for new
machine
2.0 to 2.6
6.0 to 7.4
Go-
Mea-
od
sured
item
Max. 3.1
Max. 8.0
PC88MR-10
No
go-
od

Advertisement