Komatsu PC88MR-10 Shop Manual page 1016

Hydraulic excavator
Hide thumbs Also See for PC88MR-10:
Table of Contents

Advertisement

40 Troubleshooting
Troubleshooting of engine (S-mode)
No.
Cause
Defective contact between
14
valve and valve seat
15 Defective piston ring
40-528
Point to check, remarks
Measure compression pressure (see
Standard value table).
(Reference: See Testing and adjusting,
"Testing compression pressure".)
Check valve clearance.
(Reference: See Testing and adjusting,
"Testing and adjusting valve clearance".)
Check exhaust gas at KDOC muffler outlet.
(Reference: See Testing and adjusting,
"Testing exhaust gas color".)
Measure compression pressure (see
Standard value table).
(Reference: See Testing and adjusting,
"Testing compression pressure".)
Check piston ring and piston ring groove.
Remedy
Correct contact
between valve and
valve seat or replace
them.
Replace piston ring or
piston.