50 Disassembly and assembly
Engine and cooling system
7. Remove clamp (11), and disconnect hose (12).
8. Remove mounting bolts (13) (3 pieces), and
remove KCCV ventilator (14) together with the
bracket.
9. Remove mounting bolts (15) (4 pieces), and
remove KCCV ventilator (14).
Installation
(PC88MR-A180-720-K-00-A)
Perform installation in the reverse order to
removal.
[*1]
Clamp (3):
3.0 to 3.5 Nm {0.30 to 0.35 kgm}
[*2]
Clamp (5):
3.0 to 3.5 Nm {0.30 to 0.35 kgm}
[*3]
Clamp (7):
3.3 ± 0.49 Nm {0.34 ± 0.05 kgm}
[*4]
Clamp (9):
3.3 ± 0.49 Nm {0.34 ± 0.05 kgm}
Refill with coolant
Refill it with the coolant to the specified level
through the coolant filler port. Run the engine to
circulate the coolant through system. Then
check the coolant level again.
Coolant:
13 l l
50-68
PC88MR-10