27.Remove clamps (54), (55), (56) and (57) at the
bottom of the floor frame.
28.Remove mounting bolts (58) (2 pieces) at the
front and rear of the floor frame. [*2]
29.Sling floor frame assembly (59), and remove it.
a Gradually sling the floor frame assembly, and
remove it while checking all the wiring and
piping are disconnected.
Floor frame assembly (60):
220 kg
PC88MR-10
50 Disassembly and assembly
Reference: Precautions for removing work
equipment control lever
Push lock (62) of plastic frame (61) in boot (60) with
a flat-head screwdriver, etc., and remove boot (60)
from console plastic cover (63).
a If you pull a portion other than lock (62) of plastic
frame (61) forcibly, you may break plastic frame
(61).
Installation
(PC88MR-H1H0-720-K-00-A)
Perform installation in the reverse order to
removal.
[*1]
a When installing the hose for the air conditioner
circuit, be careful to prevent any dirt, dusts and
water from entering into the hose.
Cab and its attachments
50-197