Fayat Group Dynapac CA25 Instruction Manual page 88

Vibratory roller
Hide thumbs Also See for Dynapac CA25:
Table of Contents

Advertisement

Fig. Air filter
1.
Clips
2.
Cover
3.
Main (primary) filter
4.
Backup (secondary) filter
5.
Filter housing
6.
Dust valve
Fig. Rear axle.
1.
Filler/level plug;
2.
Drain plug;
3.
Filler plug.
02-17-2021
Air filter – Replace the primary and
secondary air filters
Change the air cleaner's main filter when the
warning lamp on the display lights when the diesel
engine is operating at full speed
Release the clips (1), pull off the cover (2), and pull out
the main filter (3).
Remove the backup filter and replace (4).
Clean the air filter if necessary, see section Air Filter -
Clean.
When replacing the main filter (3), insert a new filter and
refit the air cleaner in the reverse order.
Check the condition of the dust valve (6); replace if
necessary.
When refitting the cover, make sure that the dust valve is
positioned downwards.
Rear axle differential - Oil change
Never work under the roller when the engine is
running. Park on a level surface. Block the
wheels securely.
Clean and remove the three level/filler plugs (1) and (3)
and all three drain plugs (2).
The level/filler plugs are located on the front and rear of
the axle, and the drain plugs are located on the underside
and rear. Drain the oil into a container. The volume is
approx. 12,5 liters (13,2 qts).
Deliver the drain oil to environmentally correct
handling.
Refit the drainage plugs and top up with fresh oil until the
correct level is reached. Refit the level/filler plugs. Use
transmission oil, see Lubricant Specification.
See lubricant specification.
4812325897EN
Maintenance – 1000 h
88