Fig. Drum gearbox
1.
Drain plug
2.
Filler plug
3.
Level plug
Fig. Electrolyte level in the battery:
1.
Cap;
2.
Electrolyte level;
3.
Plate.
02-17-2021
Drum gearbox - Oil change
Place the machine on a flat surface so that the plugs (1)
and (2) are in the position shown in the figure.
Clean and remove the plugs (1) (2) (3) and drain the oil
into a container with a capacity of approximately 3,0 liters.
Replace the plug (1) and fill up with oil up to the level plug
(3) in accordance with the instructions under "Drum
gearbox - Oil level check".
Use transmission oil (see lubricant specifications).
Clean and refill the level plug (3) and filler plug (2).
Battery - Check condition
Remove the cap (1) and check that the electrolyte level (2)
is about 10 mm above the plates. If the level is low, fill up
with distilled water to the correct level.
If the ambient temperature is below freezing point, the
engine should be running for some time after adding the
distilled water. Otherwise there is a risk of the electrolyte
freezing.
Check that the ventilation holes in the element caps are
clogged and then place the cap.
The cable shoes should be clean and tightened. Corroded
cable shoes should be cleaned and greased with acid-
proof vaseline.
Be careful when washing with high pressure water and do
not place the jet nozzle too close to the radiator.
When disconnecting the battery, always disconnect the
negative cable first. When connecting the battery, always
connect the positive cable first.
Dispose of batteries properly. The battery
contains environmentally harmful lead.
When performing welding work on the machine,
disconnect the battery cable and then all the cables
connected to the alternator.