6

Protect Function

♦ Set Over-Voltage Protection
♦ Set Over-Current Protection
♦ Set Over-Power Protection
♦ Set Under-Current Protection
♦ Set Under-Voltage Protection
♦ UUT Over-Temperature Protection
♦ Sense abnormal protection function
♦ Over-Temperature Protection
♦ Set foldback protection
this series power supplies provide the following protection functions. You can
set these functions in the Protect menu. Press [Shift]+[R-set] (Protect) key to
enter into Protect menu. The descriptions of protect menu are listed in the table
below.
Protect
Protection function menu
Over-voltage protection.
OVP
Off
On
Over-current protection.
OCP
Off
On
Over-power protection.
OPP
Off
On
UUT Over-temperature protection.
UUT OTP
Off
On
Under-current protection.
UCP
Off
On
Copyright © Itech Electronic Co., Ltd.
Protect Function
Turn the OVP function off.
Over-voltage protection point.
Level
Delay
Delay time.
Turn the OCP function off.
Over-current protection point.
Level
Delay
Delay time.
Turn the OPP function off.
Over-power protection point.
Level
Delay
Delay time.
Turn the UUT OTP function off.
UUT OTP point
Level
Turn the UCP function off.
Warm-up
Warm-up time.
Under-current protection point.
Level
Delay
Delay time.