Enable The Output; Set The Internal Resistance; Set The Output-On/Output-Off Delay - Cal Power IT-M3400 Series User Manual

Table of Contents

Advertisement

5. Use right and left keys or knob to setting the V-Fall Time and press [Enter]
6. Press [Esc]exit.

4.6 Enable the Output

User can press [On/Off] key on the front panel to control the instrument output.
When receive the On/Off command, the instrument enable or disable the output
according to the On/Off delay time. If the On/Off delay time set to 0, the source
enable or disable output immediately. Detailed information of On/Off delay time
refers to

4.7 Set the Internal Resistance

This function is used to simulate the internal resistance of battery in battery
simulation test, and it can simulate the real working state of many kinds of
batteries accurately. The steps of setting as follows:
1. Press [Shift]+[V-set] (Config) to enter the Config menu.
2. Rotate the knob to select Output R and press [Enter] to modify.
3. Use right and left keys and knob to set the resistance value and press
4. Press [Esc] to exit.

4.8 Set the Output-On/Output-Off Delay

You can set the output-on/output-off delay time within the range from 0 seconds
to 10 seconds.
to confirm.
4.8 Set the Output-On/Output-Off
When [On/Off] key is lit, indicates the output is enabled, the VFD displays
source present run mode.
When [On/Off] key is lit, indicates the output is disabled, the VFD displays
source state is OFF.
Except front panel and SCPI OUTPut ON /OUTPut OFF, you also can control
the On/Off state through 8–pin of analog interface ( optional ) .
The range of Output R refer to corresponding specification.
[Enter] to confirm.
Copyright © Itech Electronic Co., Ltd.
Output Function
Delay.
47