Parallel Function (Parallel)

Parallel operation allows the user to connect multiple power supplies
simultaneously to create a system with higher total current and power.Each
parallel system (group) supports up to 16 single units (1 master and 15 slaves)
for parallel connection. Power and current expand 16 times.
In parallel connection system, the master instrument needs to be set group
number, the group number range is between A to H, and the slave instrument
needs to set the master group number that slave belongs to. In each group, one
instrument must be the master unit and all other instruments connected in
parallel are slave units. All features are set up from the master unit.
Each parallel system (group) supports up to four single units (1 master and 3
slaves) for parallel connection. Each system bus link can connect up to 16
single units and support up to 16 parallel systems (groups). The units models in
each parallel system (group) must be the same. Multi-channel or
synchronization systems can be composed of multiple parallel systems (-
groups) on a System Bus link, and the units in Group A and Group B can be the
same series but different models.
Configure One Group
Take three power supplies for instance, set them to one master unit and two
slave units. The detailed connection method and procedures are as follows.
In the parallel system, the master unit executes all features, but you need to
connect all units output terminals to DUT due to the output terminals of a
single unit can not deliver higher rated current.
Copyright © Itech Electronic Co., Ltd.
Parallel Function (Parallel)
99