Cal Power ITech IT6860B Series User Manual

Programmable dc power supply

Advertisement

Quick Links

Via Acquanera, 29
22100 Como
tel. 031.526.566 (r.a.) fax 031.507.984
info@calpower.it
www.calpower.it
User Manual
Programmable DC power supply
IT6860B series
Model IT6861B/IT6862B/IT6863B
IT6860B User manual
© Copyright 2011 All Rights Reserved
Ver1.1/JUN, 2011/ IT6800A-603
1
用户使用手册

Advertisement

Table of Contents
loading

Summary of Contents for Cal Power ITech IT6860B Series

  • Page 1 IT6860B User manual Via Acquanera, 29 22100 Como tel. 031.526.566 (r.a.) fax 031.507.984 info@calpower.it www.calpower.it User Manual Programmable DC power supply IT6860B series Model IT6861B/IT6862B/IT6863B © Copyright 2011 All Rights Reserved Ver1.1/JUN, 2011/ IT6800A-603 用户使用手册...
  • Page 2: Table Of Contents

    IT6860B User manual Security ..........................3   Security regulation ......................3   Safety symbols ........................3   Certification and Quality Assurance ................. 3   Chapter1 Inspection and Installation ....................5   1.1 Inspection ..............................5  1.2 To Rack Mount the Instrument ......................... 6  1.3 The size of the power supply ........................
  • Page 3: Security

    IT6860B User manual IT6860B Series Programmable DC Power Supplies Security Please do not install replacement parts in the instrument, or perform any unauthorized modification. Please send the instrument to our company's maintenance department for maintenance, to ensure its security features. Please refer to the manual for specific information warning or precautions to avoid personal injury or equipment damage.
  • Page 4 IT6860B User manual Warranty Service For the warranty service or repair the product, the product must be returned to the designated maintenance units. Return the product to us for warranty service, the customer should pre-pay the one-way Freight to the maintenance department. And our company is responsible for the return shipping cost.
  • Page 5: Chapter1 Inspection And Installation

    IT6860B User manual intelligent test platform Model Voltage Current Power IT6861B 0~20V/ 0~8V 0~5A/ 0~9A 0~100W/ 0~72W IT6862B 0~32V/ 0~12V 0~3A/ 0~6A 0~96W/ 0~72W IT6863B 0~72V/ 0~32V 0~1.5A/ 0~3A 0~108W/ 0~96W Chapter1 Inspection and Installation Power supply is high level safety equipment; there is a protected ground terminal. Before Installation or operation, please read the safety signs and instructions in this manual 1.1 Inspection After received the power supply, follow these steps to check it:...
  • Page 6: To Rack Mount The Instrument

    IT6860B User manual The power input requirements There are two kinds of working voltage for the power supply: 110V and 220V, so please pay attention to the working input voltage. There is a power cord which matches with your local power in the attachment.
  • Page 7: The Size Of The Power Supply

    IT6860B User manual PIC 1.3 To rack mount two instruments side-by-side, order rack mount kit IT-E151, you needn’t to use the front cover panel. 1.3 The size of the power supply The size of IT6860B series power supply 214.5mmW×88.2mmH×354.6mmD * refer to the below: Dimensions Unit: MiliMeter(mm)...
  • Page 8: Chapter 2 Quick Start

    IT6860B User manual Chapter 2 Quick Start This chapter introduces the front panel, the rear panel, key functions and VFD display function of the IT6860B power supply, make sure that you can quickly know the appearance, instruction and the key function before you operate the power supply, Help you make better use of this series of power supply.
  • Page 9: Keypad Introduction

    IT6860B User manual Cooling window Remote sense terminal RS232 communication interface USB communication interface (fuse contained) power socket GPIB communication interface Note: the AC power switch is at the bottom of the power supply. To avoid any damage, please make sure it is in the right position before you power on the supply. 2.2 Keypad introduction Keypad description, see the table below: Keys...
  • Page 10: Vfd Description

    IT6860B User manual Power on key Power Numeric keys Voltage set key, set the output voltage/over voltage protection point V-set V-set for the power supply Current set key, set the output current/menu function key, to set the I-set I-set Menu relevant Parameters for the power supply Callback key to call up a set value of system parameters already Recall...
  • Page 11: Chapter 3 Power On Check

    IT6860B User manual Shift key is pressed,Use The power supply has error or Shift Error compound keys fault The power supply is in OVP OVP function is enabled Prot /OTP protection Not in use Keypad is locked Lock Chapter 3 power on check This chapter will introduce the procedure of power on check for IT6860B, including pre-check and output check, to make sure the power supply can power on and work normally on the original state.
  • Page 12: 1.Power On The Power Supply

    IT6860B User manual Note:If the power supply is used to charge a battery, please pay attention to the positive and negative polarity to avoid any damage. Power on pre-check includes two parts: power on the supply and system self check. 1....
  • Page 13: 2.System Self-Test

    IT6860B User manual Use the same specification of fuse to replace the old one,install it to the fuse box and then insert .           2. System self-test After power on normally, the supply will enter self -test first. During this time, the following should be displayed: INIT….
  • Page 14: Output Verification

    IT6860B User manual 3.2 Output Verification IT6860B is dual range output, the following procedures verify that the power supply outputs the correct voltage and current levels and properly responds to entries from the front panel.  1. Voltage Output Check The following steps verify basic voltage functions without load.
  • Page 15: Chapter 4 Specification

    IT6860B User manual 7 ) Adjust the current value Set some different current values, check whether the voltage value on VFD is near 0v, and the current on it is close to the value you set. 8) Make sure that the current can be adjusted from 0 to full rated value. Low voltage range current check:...
  • Page 16: Supplementary Characteristic

    IT6860B User manual (20V/5A) (32V/3A) (20HZ-20M) ≤3mVp-p and ≤4mVp-p and Normal mode 1mVrms 1mVrms Voltage (8V/9A) (12V/6A) Normal mode <9mArms <7mArms <6mArms Current Common mode <1.5uArms <1.5uArms <1.5uArms Current Transient Recover to 75mV <50uS <50uS <50uS response time (50%~100%load) <90ms <90ms <90ms Rise time...
  • Page 17: Chapter5 Front-Panel Operations

    IT6860B User manual Chapter5 Front-panel Operations This chapter introduces the basic operations of IT6860B.It is divided into following parts:  local/remote  Voltage setting  Current setting  Output on/off  Switching the setting value and actual value  Dual-range switch ...
  • Page 18: Current Setting

    IT6860B User manual Enter button to confirm. 5.4 Current setting IT6860B series power supply enables customer to set current from 0V to rated value. Press I-set I-set button, it will be lit. Now, there are three ways to set the voltage: I-set I-set Solution1: press...
  • Page 19: Trigger Operation

    IT6860B User manual Save operation: Set the desired Voltage and Current value Enter Recall Press the (Shift) + +number 1 to 9 to assign a memory location. Press confirm. Recall operation: Recall Keep group setting unchanged, press +number 1 to 9 to select the memory location where the settings you want to recall are stored.
  • Page 20 IT6860B User manual on/off state will be recalled automatically. Set GPIB address GPIB ADDR Baudrate set 4800 9600 BAUD 19200 38400 57600 COMM RS232 11.52K NONE NONE 8BIT None parity 8BIT 8BIT EVEN 8BIT Even parity 8BIT 8BIT Odd parity 8BIT Set to SCPI protocol Single unit to communicate with PC...
  • Page 21: Menu Function

    IT6860B User manual Select minute as time unit (SEC) Set step voltage VSET Set step current ISET Set step delay time(0.1-9999) Continue to edit the next step NEXT finish list file edit (YES) Set repeat count REPET 1-65535 Do not save the current list file. In this mode, the file can only run for one time.
  • Page 22 IT6860B User manual Power up setting (>P-MEM) P-MEM item is used to set operation parameters state of power supply after power up. If select RESET, means to initialize output parameters to factory default setup. Every time you power up the unit, the output parameters is always 0V, 0A. If select KEEP, means to remember last shutdown parameters.
  • Page 23 IT6860B User manual Trigger Mode(>TRIG ) IT6860B series power supply supports two different trigger modes (MANU and BUS). Enter If select MANU, press (Shift) + (Trigger) can generate a trigger signal. If select BUS, then sending command *TRIG can generate a trigger signal. Factory default set is MANU.
  • Page 24 IT6860B User manual TRIG=MANU MEM=GROUP1 TIMER=OFF List Function (>List Set) List mode allows you to create a sequence of steps, store it into the power supply’s non volatile memory and execute it. The input parameters for generating a list include the time unit (min or sec), the step voltage, step current, step time and whether continue to the next step, repeat count and whether save the file.
  • Page 25: Ovp Function

    IT6860B User manual If you select to save the list file, VFD will display LIST EDIT after blinking contents of SAVE DONE for about three seconds. 14) Press two times to exit menu operation. 15) After you edit a list file, set the trigger source in the menu to “MANUAL” Enter On/Off 16)...
  • Page 26: Key Lock

    IT6860B User manual 5.12 KEY LOCK On/Off Press (Shift) + (Lock) button to lock the function keys. If successfully be locked, a mark of “LOCK” will appear on the front panel. Meanwhile, all the function keys will be disabled except ON/OFF, Meter and Shift buttons. On/Off Press (Shift) +...
  • Page 27: Chapter6 Remote Operation

    IT6860B User manual Chapter6 Remote Operation IT6860B series power supply provides two standard communication interfaces: RS232、 USB,GPIB.User can select anyone to communicate with the computer. 6.1 RS232 interface There is a COM port (DB9)connector at the rear of the power supply, when connect to computer, you need to connect a cable with COM port on both side;...
  • Page 28 IT6860B User manual Description number No connection TXD, transfer date RXD, receive data No connection GND, ground No connection CTS, clear transfer RTS, ready to transfer No connection RS-232 Troubleshooting: If there is RS-232 connection problem, check the following: Computer and power supply must configure the same baud rate, parity, data bits and flow control options.
  • Page 29: Usb Interface

    IT6860B User manual Parity=None Start Bit 8 Data Bits Stop Bit 6.2 USB interface Use a Cable with two USB port to connect the power and the computer. All power functions can be programmed via USB. The USB488 interface functions of the power supply described as below: ...
  • Page 30 IT6860B User manual Q&A 1. Specification of leads The following table enumerates the max current which AWG copper could bear: current(A) Note: AWG is the short of American Wire Gage which indicates X lead (it is marked on the lead). The parameters on the above table are for single lead in 30 ℃ working temperature.
  • Page 31 IT6860B User manual When test battery, the main reason of no start is that battery (residual voltage) discharges capacitors of positive and negitive terminals of the power supply. Method to avoid no start: connect a switch which is parrallel with a current limiting discharging resistor.
  • Page 32 IT6860B User manual Support process If you have a problem, follow these steps: 1 Check the documentation that come with the product 2 Visit the ITECH online service Web site is www.itechate.com , ITECH is avaliable to all ITECH customers. It is the fastest source for up-to-date product information and expert assistance and includes the following features: Fast access to email AE Software and driver updates for the product...

This manual is also suitable for:

Itech it6861bItech it6862bItech it6863b

Table of Contents