4

Output Function

♦ Set the Output Priority Mode

♦ Set the Output Voltage
♦ Set the Output Current
♦ Set the Output Power
♦ Set Output Slope
♦ Enable the Output
♦ Set the Internal Resistance
♦ Set the Output-On/Output-Off Delay
4.1 Set the Output Priority Mode
This series instrument can set the output priority mode like CV priority or CC
priority.
The following figure shows the CV/CC priority operating locus of the output. The
area in the white quadrants shows the output as a source (sourcing power). The
area in the shaded quadrants shows the output as a load (sinking power).
CV priority mode:
Voltage priority mode keeps the output voltage constant. In voltage priority
mode, the output voltage should be set to the desired value. A positive and
negative current limit value should also be set. And the output is controlled
by a constant-voltage feedback loop, which maintains the output voltage at
its programmed setting as long as the load current remains within the
positive or negative current limit settings.
Current priority mode keeps the output current constant. In current priority
mode, the output current should be programmed to the desired positive or
negative value. Voltage limit range should also be set. And the output is
controlled by a bi-polar constant current feedback loop, which maintains the
output source or sink current at its programmed setting. The output current
remains at its programmed setting, provided the load voltage remains within
the voltage limit setting.