Read-back current
Read-back Voltage
Read-back Power
Temperature
Coefficient
Load Regulation
Line Regulation
Ripple
Rise time
Rise time
Fall time
Fall time
OCP
OVP
OPP
Voltage programming
Output Read-back
Range
Resolution
Accuracy
Range
Resolution
Accuracy
Range
Resolution
Accuracy
Temperature Coefficient
Voltage Tempera-
ture Coefficient
Current Tempera-
ture Coefficient
Regulation
Voltage
Current
Voltage
Current
Ripple
Voltage
Current
value voltage rise/fall time
Voltage(No load)
Voltage(Full load)
Voltage(No load)
Voltage(Full load)
Output Protection range
External analog (optional)
Copyright © Itech Electronic Co., Ltd.
Technical Specification
-6A~6A
0.1mA
<0.1% Imax+0.1%Icurrent
0-300V
10mV
<0.1% Umax
-200W~200W
0.1W
<1% Pmax
100ppm/℃
50ppm/℃
≤0.05% Umax
≤0.05% Imax
≤0.05% Umax
≤0.05% Imax
≤600mVp-p
≤30mArms
20ms
50ms
20ms
20ms
-6.2A or 6.2A
305V
-210W or 210W
External 0V~10V is 0~300V
124