RS–232 Configuration
The user needs to configure the RS–232 interface parameters in the system
menu before using the remote control. The RS–232 interface parameters are as
follows.
Name
Baud rate
Data Bit
parity bit
stop bit
The operation steps are as follows.
1. Press [Shift]+[P-Set](System) to enter into the system menu interface.
2. Use left and right keys or rotate the knob to select I/O Config and press
3. Use left and right keys or rotate the knob to select RS-232 and press [Enter]
4. Rotate the knob to set the baud rate and press [Enter] to confirm.
5. Press [Esc] to exit.
RS-232 Troubleshooting
If you meet some problems when communicating with PC by RS-232 interface,
please check the following items:
Description
Select the baud rate from the following options: 4800/9600/
19200/38400/57600/115200
8 (fixed)
None (fixed)
1 (fixed)
[Enter] key to confirm.
key to confirm.
1:RS232 = 9600_8_N_1
PC and power supply must have the same baud rate.
Copyright © Itech Electronic Co., Ltd.