2.

Menu Function

Maximum voltage(>MAX VOLT)
The maximum voltage can be adjusted from 0A to maximum rated voltage of each model.
To set max volt:
(1) Press
(Shift) +
Enter
and press
(2) Using
Output voltage set will be limited within the range of max voltage.
MAX VOLT default set is the rated voltage of each model.
(SEC)
MIN
Set step voltage
VSET
Set step current
ISET
Set step delay time(0.1-9999)
SEC
YES
NEXT
(YES)
NO
REPET
1-65535
NO
SAVE
FILE0-FILE3
Quit list menu
Model information
Firmware version
First six number of SN
Middle six number of SN
Last six number of SN
Quit information menu
I-set
I-set
(Menu) button to enter menu setup, scroll to >MAX VOLT item
to confirm.
button to adjust cursor position and set max voltage.
IT6860B User manual
Select minute as time unit
Continue to edit the next step
finish list file edit
Set repeat count
Do not save the current list file. In this
mode, the file can only run for one time.
Once you quit the list mode or turn off
the unit, the file cannot be recalled.
save list file to assigned memory
location