Cal Power IT-M3400 Series User Manual page 64

Table of Contents

Advertisement

Recall and view List files
If several List files have been edited, select one List file for execution. Or, the
user can view information of the recalled List file in the recall interface.
1. In the List function setting interface, select "Recall", and press [Enter] key
2. Rotate the knob to set the number of List file to be recalled. Press [Enter]
3. After successful recall, the user can view the setting information of the exist-
4. Rotate the knob, select "List Setup", and press [Enter] key for confirmation.
5. Rotate the knob, select "View Step=1/6", and press [Enter] key for confirma-
6. Press [Esc] key, and exit the existing page.
Run List file
After the List files are edited, the user needs to enable the List function and re-
turn to the main interface to trigger the running.
"Delete all= No/Yes": When "Yes" is selected, clear all steps in the exist-
ing List file, and recover all attribute values to system default values.
When "No" is selected, do not clear steps.
"Copy File 1 to 2": Execute this step and copy existing List 1 file to List 2
file.
for confirmation.
key to enter the viewing interface.
When the selected number is empty, the interface would prompt that the re-
called file is empty. The user needs to select the file again or return and en-
ter the Edit menu for editing.
ing List file. The following parameters can only be viewed, and cannot be
edited. To modify them, please return and enter the Edit menu to select the
corresponding file number for editing.
1: List Setup
2: View Step=1/6
Rotate the knob to view the attribute parameters of the List file in successive.
The contents are consistent with the List Setup contents during editing of the
List file.
tion. Set the number of List step to be viewed, and press [Enter] key to enter
the parameter viewing page of the selected Step.
S001 Value=1.000V
S001 Slope=0.001S
S001 Time=0.005S
S002 Value=2.000V
S002 Slope=0.001S
S002 Time=0.005S
...
Rotate the knob for scrolled viewing of parameters of all Steps of the List.
The voltage and current parameters in the step vary with the existing List
mode.