Temperature
Coefficient
Load Regulation
Line Regulation
Ripple
Rise time
Rise time
Fall time
Fall time
OCP
OVP
OPP
Voltage programming
Voltage monitoring
Current programming
Current monitoring
Voltage range
OVP
UVP
Resolution
Accuracy
Temperature Coefficient
Voltage Tempera-
ture Coefficient
Current Tempera-
ture Coefficient
Regulation
Voltage
Current
Voltage
Current
Voltage
Current
value voltage rise/fall time
Voltage(No load)
Voltage(Full load)
Voltage(No load)
Voltage(Full load)
Output Protection range
External analog (optional)
AC parameters
Copyright © Itech Electronic Co., Ltd.
<1% Pmax
100ppm/℃
≤0.05% Umax
≤0.05% Imax
≤0.05% Umax
≤0.05% Imax
Ripple
≤1200mVp-p
≤30mArms
-3.1A or 3.1A
-410W or 410W
External 0V~10V is 0~600V
External 0V~10V is 0~600V
External -10V~10V is -3A~3A
External -10V~10V is -3A~3A
100VAC -240VAC
264VAC
90VAC
Technical Specification
0.1W
50ppm/℃
30ms
60ms
30ms
30ms
610V