Cal Power IT-M3400 Series User Manual page 79

Table of Contents

Advertisement

Enable UVP
1. Press [Shift]+[R-set](Protect) to enter Protect menu interface.
2. Rotate the knob to select UVP and press [Enter] key to confirm.
3. rotate the knob to select On and press [Enter] key to confirm.
4. Rotate the knob to adjust the warm-up time Warm Up and press [Enter] key
5. Rotate the knob to adjust the under-voltage limit Level and press [Enter] key
6. Rotate the knob to adjust the delay time Delay and press [Enter] key to
7. Press [Esc] to exit.
Warm-up time
You can specify the warm-up time for UVP protection to make the instrument
not judge the under-voltage protection fault within the specified warm-up time.
Delay time
You can specify an UVP delay to prevent momentary output settings, DUT and
status changes from tripping the under-voltage protection. In most cases these
momentary conditions would not be considered an under-voltage protection
fault, and having an UVP condition disable the output when they occur would be
a nuisance. Specifying an UVP delay lets the UVP circuit ignore these
momentary changes during the specified delay period. Once the UVP delay
time has expired and the under-voltage condition persists, the output will shut
down.
Clear Under-voltage Protection
When under-voltage protection occurs, the instrument responds as follows:
To clear the under-voltage and return to normal operation, firstly remove the
conditions that caused the protection fault. Press [Esc] key (or send the
command PROTection:CLEar) to clear the protection status. The "Under
Enable UVP;
The output time exceeds the warm-up time;
The output voltage value is less than the set voltage protection point Level
and the period is greater than the set protection delay time Delay.
to confirm.
to confirm.
confirm.
Instrument output is off;
The buzzer sounds;
The interface displays "Under Voltage Protect" and flashes;
Status register, the UV status bit is set to 1;
Copyright © Itech Electronic Co., Ltd.
Protect Function
68

Advertisement

Table of Contents
loading

Table of Contents