6.3.3 Setting the pump running mode

PRG.
SET
ENTER
RUNNING MODE?
PRG.
S.ENERGY MODE: Enables the energy-saving operation.
NORMAL MODE: Enables the rated operation.
The mode which is currently not set is displayed.
If you do not need to set, press the key

6.3.4 Setting the normal rotational speed

ENTER
SET BP
NORMAL SPEED?
PRG.
Use the up and down arrow keys to change the setting value.
▲ ▼
▲ : Increase the setting speed by 0.1 kmin
▼ : Decrease the setting speed by 0.1 kmin
Upper limit BP : 6.0 kmin
Lower limit BP : 3.0 kmin
Factory Setting : 6.0 kmin

6.3.5 Setting the low rotational speed

ENTER
SET BP
LOW SPEED?
PRG.
▲ ▼
Use the up and down arrow keys to change the setting value.
▲ : Increase the setting speed by 0.1 kmin
▼ : Decrease the setting speed by 0.1 kmin
Upper limit BP : 6.0 kmin
Lower limit BP : 1.0 kmin
Factory Setting : 3.0 kmin
S.ENERGY MODE?
NORMAL MODE?
to go back to the previous screen.
PRG.
BP NORMAL SPEED
ENTER
-1
#.# kmin
-1
.
-1
-1
-1
-1
BP LOW SPEED
ENTER
-1
#.# kmin
-1
.
-1
-1
-1
-1
(42)
Setting done
ENTER
Setting done
ENTER
SETTING COMPLETED
SETTING COMPLETED