List of all supported CVs
CV
Surname
adjust Speed
23
adjust brakes
24
braking mode
27
RailCom® configuration
28
description
Factor to adjust the acceleration time CV 3. Values ​ ​ f rom 0 to 127 will be added to the CV.
3 If the values ​ ​ a re to be subtracted, in addition, bit 7 set (value 128).
Factor for adjusting 4. values ​ ​ f rom 0 to 127, the braking time CV will be added to the
CV. 3 If the values ​ ​ a re to be subtracted, in addition, bit 7 set (value 128).
permitted braking modes
function
bit
ABC braking, voltage greater than at the right side
0
ABC braking, voltage is greater on left side
1
ZIMO HLU brakes active
2
Brake on DC, when polarity opposite the direction of travel
3
Brake on DC, when polarity the same as the direction of travel
4
Selectrix® braking diode locomotive brakes when polarity
5
opposite the direction of travel
6
Selectrix® braking diode locomotive brakes when polarity the same as the direction of
travel
7
Locomotive brakes with a constant braking distance when FS = 0
Settings for RailCom®
function
bit
Channel 1 released for broadcast address
0
Data transmission allowed on the channel 2
1
RailCom® Plus automatic Lokanmeldung active
7
range value
0 - 127
0
28
value
1
2
4
8th
16
32
64
128
131
value
1
2
128