Advertisement

Quick Links

User Manual
LokSound V3.0 / V3.5
LokSoundXL
LokSound micro
4 th edition, August 2005
user manual LokSound / LokSoundXL V3.5, 4 th edition, 08/2005
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LokSound V3.0 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Esu LokSound V3.0

  • Page 1 User Manual LokSound V3.0 / V3.5 LokSoundXL LokSound micro 4 th edition, August 2005 user manual LokSound / LokSoundXL V3.5, 4 th edition, 08/2005...
  • Page 2: Table Of Contents

    Index contens Introduction ............................3 Characteristics of the LokSound decoders ................... 4 Installation of LokSound decoders ...................... 5 3.1. Connecting LokSound decoders in HO, TT, N, O gauge models ............5 3.1.1 Installation requirements ........................5 3.1.2 Engines with DCC interface ......................... 7 3.1.3 Engines without interface ........................
  • Page 3: Introduction

    If you adhere to these warnings your LokSound decoder the following remarks: will reward you with trouble-free operation and long life. ESU electronic solutions ulm GmbH & Co. KG Please read this manual carefully before August 2005 carrying out the installation!!! Although...
  • Page 4: Characteristics Of The Loksound Decoders

    LokSoundXL is best suited for larger scales such as O, load control. It may be adapted to suit each individual I, II and G gauge. ESU LokSound decoders revolutionize motor and can be switched off. Suitable for DC motors any model train layout. They intelligently combine a and coreless motors.
  • Page 5: Installation Of Loksound Decoders

    Installation of LokSound decoders 3. Installation of LokSound decoders Please make sure that the total current does 3.1. Connecting LokSound decoders in N, not exceed the maximum permitted current TT, H0, 0 gauge models for the function outputs and avoid short circuits between the outputs: LokSound 3.1.1 Installation requirements circuits are protected but an external voltage...
  • Page 6 Engines with DCC interface speaker100Ω violet green yellow white 2 x dark brown AUX 1 head rear AUX 2 LokSound LokSound light light LokSound blue orange gray black engine Figure 2 Figure 2 Figure 2 Figure 2 Figure 2: Wiring of engines with DC motor and isulated functions speaker100Ω...
  • Page 7: Engines With Dcc Interface

    Engines without interface LokSound decoders have a certain size: make sure, 3.1.3 Engines without interface that the decoder fits easily into the engine, that no Not every engine has a digital interface and thus the pressure is applied when replacing the housing onto wiring becomes more elaborate: Disconnect any the chassis and that no wires are squeezed between existing wires within the engine and any connection...
  • Page 8: Connecting Dc Motors

    Figure 5: Figure 5: LokSound decoders may only be used with the speakers supplied by ESU GmbH & Co. KG . They have an impedance of 100 Ohm. The use of speakers from others manufactures may cause considerable distortion and in extreme cases, may even destroy the LokSound decoder.
  • Page 9: Connecting Auxiliary Function Devices

    Connecting auxiliary function devices Please handle speakers with extreme care: Make sure that the total current for the don’t apply pressure or touch the membrane! function outputs does not exceed the The speaker’s magnets are very powerful! Keep permitted current rating and avoid short all metal items away and secure the speaker circuits between outputs.
  • Page 10: General Hints

    Connecting the LokSoundXL decoder 3.2. Connecting the LokSoundXL decoder 3.2.1 General hints The LokSoundXL decoder is partly supplied as an open When modifying an engine for digital operation circuit board. Do not remove the shrink sleeve, as please take note of the following: there will be no warranty.
  • Page 11: Connecting A Dc- Or Coreless Motor

    Please make sure you do not confuse the You may only use the specially adapted speakers (1 terminals. Wrong wiring may cause damage Watt, 32 Ohm) provided by ESU GmbH & Co. KG for or destruction of the decoder – despite the LokSoundXL decoders.
  • Page 12 Connecting the LokSoundXL decoder rail left right DC Motor Figure 8: Figure 8: Figure 8: Figure 8: Figure 8: Connecting the LokSoundXL decoder User Manual LokSound / LokSoundXL V3.5, 4 th edition, 08/2005...
  • Page 13 Connecting the LokSoundXL decoder Figure 9: Figure 9: Figure 9: Figure 9: Figure 9: Connecting the LokSoundXL decoder user manual LokSound / LokSoundXL V3.5, 4 th edition, 08/2005...
  • Page 14: Auxiliary Function Outputs

    Auxiliary function outputs short intervals. The lamps have to be replaced by 3.2.5.1 Auxiliary function outputs others that are suitable for 19 Volts. LokSoundXL has 8 (!) function outputs, two of which are reserved for headlights. The remaining 6 (AUX 1 through AUX 6) can be used for lighting, smoke 3.2.5.3 Connecting auxiliary functions generators, couplers, etc.
  • Page 15: Connecting A Hall Sensor

    Connecting a Hall sensor reed switch (SRK) reed drive wheel switch(SRK) resistor 10k 0,25W Figure10c: Figure10c: Figure10c: Figure10c: Connecting external Reed switch Figure10c: Figure 10a: Figure 10a: Figure 10a: Figure 10a: Figure 10a: Connecting a reed switchwith magnet 3.2.7 Connecting additional reed switch miniature magnet LokSoundXL decoders have two additional inputs that can trigger various functions.
  • Page 16: Analogue Operation

    Analogue operation After installation you may test the LokSound decoder 4.2 Digital operation as follows: 4.1.2 AC operation with conventional please check all connections carefully using an Ohm- Märklin® controller meter: - are there any short circuits between the motor terminals and the wheel pick-ups? Operation with conventional Märklin®...
  • Page 17: Adjusting Decoder Parameters

    Adjusting decoder parameters Please note that not all CVs have factory pre-set 5. Adjusting decoder parameters values: Chapter 5 provides information on how to change Some CV values vary depending on the type of sound the settings of LokSound decoders. Please take your effect.
  • Page 18: Back Emf Control (Load Control)

    Back EMF control (load control) case you have to reduce the value for CV 56, in the 5.2.1 Back EMF control (load control) first case increase the value. The internal PI regulation LokSound decoders utilize fourth generation load of LokSound can be adjusted with CV 54 and CV 55. Control assuring constant speed regardless of the Depending on the type of motor the parameters may actual load when using DC motors.
  • Page 19: Speed Curve

    This method permits optimizing the when programmed as follows: running performance. This mode is also activated via CV 29. We recommend the use of the ESU Lok- CV 54 = about 20 – 25 Programmer and its software for easy calculation CV 55 = 38 and programming.
  • Page 20 Speed Curve • Dimmer: normal, continuous power to load Examples • Example 1: smoke generator on AUX 1 and F5. • Blinking light: the output blinks with an adjustable Let’s assume you want to control a smoke generator frequency with function button F5 that should be connected to •...

This manual is also suitable for:

Loksound v3.5Loksound xlLoksound micro

Table of Contents