adjusting your driving behavior

10.8.2. AC analogue mode

Using the CV127-Start can be set at which the loco in analog - will set off AC
operation. With CV128 the speed limit in analog is - AC operating set.
The motor is switched off again as soon as the transformer voltage is below a
certain value. This value is normally equal to the turn-on (CV127), but can also
be reduced by an "offset". This offset is stored in CV 130th
Regardless of the motor functions (light, sound) at a different, usually lower
voltage advance eingeschal- tet can be. If this is desired, the "offset" in CV is
written 129th
The behavior can be described as follows: motor on
engine off
features a
functions

10.9. engine brake

The LokSound decoder 5 may wish to short-circuit the motor during the stand.
This "parking brake", the displacement roll of the locomotive at the slope and
prevent the curl comparable wrestlers.
The engine brake can be switched on by setting bit 6 in CV 124 einge-.
The engine brake is effective only while the power is on track.
62
CV 127
CV 127 - CV 130
CV 127 - CV 129
CV 127 - CV 129 - CV 130

10.10. Configuring Power Pack

If you connect a "Power Pack", you can determine men, after which time the
decoder off. Responsible is CV 113. There you can determine (as a multiplier of
0.032768 seconds) the date after the decoder off on. You may wish to choose a
time between 0.3 and 1.0 seconds to go in an emergency, your locos not too far.
In order for the Power Pack also works in charge of the charge function output
must be con- figured (AUX9 at LokSound, AUX7 at LokSound micro) on the
"Power Pack Control".
First, write in CV 31 = 16, 32 CV = 0. Set thereafter for LokSound
(AUX9) CV339 = 31 Insert thereafter for LokSound (AUX7) CV323 =
31st