To Remove The Tape Drive - Nortel CallPilot 703t Maintenance And Diagnostics

Hide thumbs Also See for CallPilot 703t:
Table of Contents

Advertisement

Replacing media drives

To remove the tape drive

.
Note: The tape drive is installed in the second bay from the top.
1
Prepare the server for tape drive replacement as follows:
a. Shut down the server, and then disconnect the power and
b. Remove the side cover.
c. Remove the upper fan holder foam.
For instructions, see "Preparing the server for hardware
maintenance" on page 120.
.
2
Disconnect the power and signal (SCSI) cables of the faulty drive.
3
Open the front panel on the server.
4
Remove and save the two screws that secure the tape drive to the
front of the chassis.
5
Pull the tape drive out of the chassis, and then place it on an
antistatic surface.
Note: If you plan to leave the bay empty, install a filler panel and
stainless steel EMI shield on the bay.
6
Remove the four screws and two slide rails from the tape drive.
158
CAUTION
Risk of equipment damage
Use an ESD wrist strap to protect static-sensitive components.
peripheral device cables.
WARNING
Risk of personal injury or equipment damage
Failure to follow the procedures in "Preparing the
server for hardware maintenance" on page 120 can
result in electrical shock or equipment damage.