Replacing media drives
d. Connect the other end of the cable as follows:
e. For proper cooling and airflow, neatly fold and secure the
.
4
Connect the hard drive's power cable.
Note: The connector is keyed so that you cannot connect it upside
down.
5
At the front of the server, slide the drive into the bay until it clicks
into place.
6
Secure the drive carrier to the front of the server with the screws
you removed earlier.
Tighten the screws firmly.
7
Ensure that all media drive cable connections are secure.
Note: Connectors could be dislodged when you slide the hard drive
all the way inside the bay.
.
154
— Connect hard drive 1 to channel 0 on the RAID controller.
— Connect hard drive 2 to channel 1 on the RAID controller.
excess signal cable above the CPU. Use a tie wrap or cable clip
to secure the cable.
CAUTION
Risk of equipment damage
Ensure that any cables in the proximity of the fans
are kept away from the fans. If a cable is caught in
a fan, the fan will break.
If you need more information, see "SCSI and IDE drive cabling"
on page 146.
CAUTION
Risk of data loss, corruption, or system malfunction
If the hard drive cable connections are loose, data
loss, data corruption, or system malfunction can
occur.
Standard 1.06