January 2007
7
Connect the floppy disk drive's signal cable to the drive.
Note: The connectors are usually keyed to allow you to easily
reconnect them to the drive. If they are not keyed, insert both cables
so that the red wires are closest to the center of the drive.
.
8
Connect the power cable of the floppy disk drive to the drive.
Result: The floppy disk drive is installed.
9
Replace the upper fan holder foam.
For instructions on replacing the upper fan holder foam, see "To
replace the upper fan holder foam" on page 128.
10
Replace the side cover.
11
Reconnect the peripheral device and power cables.
12
Power up the server.
13
Test the floppy disk drive.
703t Server Maintenance and Diagnostics
CAUTION
Risk of data loss
If the floppy disk drive contains a floppy disk and the
signal cable is connected backwards, data loss can
occur. The LED at the front of the drive will also
remain lit after the server is powered up.
Replacing media drives
169