Edwards iXL600 Instruction Manual page 66

Dry pump systems
Table of Contents

Advertisement

A540-55-880 Issue D
Warning Message
'Action' Message on
on PDT
PDT
Alarm 62.12
See manual
MB E/C Temp High
Alarm 174.10
See manual
Booster Stopped
Alarm 176.01
xxxx yyyy
MB INV xxxx yyyy
aaaaaaaaaaaaaaaa
Alarm 176.01
See manual
MB Not Running
Alarm 176.13
See manual
No MB Inv Comms
Alarm 184.10
See manual
Dry Pump Stopped
Alarm 186.01
xxxx yyyy
DP INV xxxx yyyy
aaaaaaaaaaaaaaaa
Alarm 186.01
See manual
DP Not Running
Alarm 186.13
See manual
No DP Inv Comms
Page 58
Table A14 - Alarms (continued)
Possible Cause
The booster end cover
temperature has reached the
maximum allowed so the booster
has stopped.
Booster speed too low - rotor is
probably locked.
Booster Inverter has raised an
alarm and stopped the system.
Booster Inverter will not start up
when requested.
The pump controller cannot
communicate with the booster
inverter during start-up checks.
The dry pump speed is very low.
The rotor might be locked.
Dry Pump Inverter has raised an
alarm and stopped the system.
Dry Pump Inverter will not start up
when requested.
The pump controller cannot
communicate with the dry pump
inverter during startup checks
Edwards and the Edwards logo are trademarks of Edwards Limited.
Action
Refer to
Section 4.5
the temperature that triggered
the alarm.
See Warning 62.11 for causes and
actions.
Contact Edwards
Refer to
A2.3
for more
information.
Check inverter fault history.
Check the wiring between the
pump controller and the booster
inverter.
Cycle the power to the pump and
attempt to re-start. If this fails,
contact Edwards.
Refer to
A2.3
for more
information.
Check inverter fault history.
Check the wiring between the
pump controller and the dry pump
inverter
© Edwards Limited 2015. All rights reserved.