Operation Mode; Motor Parameter - Danfoss VACON 1000 Operating Manual

Hide thumbs Also See for VACON 1000:
Table of Contents

Advertisement

VACON® 1000
Operating Guide

7.6.1 Operation Mode

Use this submenu to select the operation mode and the reference set.
Operation mode options:
HMI: The drive is operated by HMI.
Digital: The drive is operated by DCS (the remote digital control of the drive, see
ic interface definition).
Communication: The drive is operated by communication, such as RS485 or Ethernet.
Reference set options:
HMI: Speed is set by HMI.
Analog: Speed is set by analog input.
Digital: Speed is set by DCS (the remote digital control of the drive, see
face definition).
Communication: Speed is set by communication, such as RS485 or Ethernet.
PID: Speed is adjusted automatically by PID module.
Illustration 60: Operation Mode Submenu

7.6.2 Motor Parameter

Use this submenu to select the motor parameters:
Multi-motor configuration
-
Select different motors through HMI, digital input, or communication.
-
Set the maximum number of motors.
Rated parameter
-
Set the rated frequency, rated speed, pole number, rated voltage, and rated current for different motors.
Speed operation configuration
-
Set the rotation direction, maximum speed, and minimum speed for different motors.
Auto tuning parameter
-
Check the parameters regarding auto tuning.
Speed controller
Flux controller
Danfoss A/S © 2021.06
Human-Machine Interface
6.9.4 Application Wiring Example
6.9.4 Application Wiring Example