4.2.2 Emergency stop inspection

It is advised to test the emergency button every time someone of the operator or service or-
ganization visits the location of the charger. This test needs to be done at least once a year e.g.
during a preventive maintenance round.
Test only when the charger is in idle mode and ready to charge:
1. Press the emergency button.
2. Reset the emergency button by turning the knob clockwise.

4.2.3 Special inspections

In the following cases the charger must be checked by ABB service personnel before further
use:
If it was struck by lightning.
If it is damaged due to an accident or fire.
If its location has been flooded.
4.3

Problem resolving

The site operator or helpdesk is the first response to a customer call. The helpdesk can remo-
tely solve simple problems for the customer.
In special cases the site operator with knowledge of the charger can be asked by ABB support
to report about the status of some internal components of the charger. Therefore a brief
description of the position and function of these components is described on the next pages.

4.3.1 Overview of the Power Cabinet

A
Door
B
Door handle / lock (per Power Cabinet
Unique system key)
Document: v0.6 / Document No.: 6AGA000008-0102-EN | Date: 22-05-2019
The indicator light (beacon) will turn red.
After a few moments, the charger returns to its idle state.
Do not open the Power Cabinet door if you are not familiar with working with high
voltage and high current.
WARNING