9
9.1
Fault Message Table for the JetMove D203
Error Number
Type of Error
F 00
Hardware Errors
F 01
Internal voltage
supply error
F 03
Motor cable
breakage
F 04
Overvoltage in
the DC link
Jetter AG

Diagnostics

Error Messages

INFO
In the case of a error message, the letter "F" and two successive numbers
appear on the 7-segment display every second.
Description
Internal hardware
defect
One or more
power supply
voltages are
beyond their limits
The motor cable is
broken
Please be careful:
The motor cable is
tested when the
drive controller is
enabled for the
first time
A DC link voltage
of> 480 V has
been detected
Response to
Troubleshooting
Errors
– Immediate
– Cut drive controller
pulse disable
from power lines
– Return the amplifier
for repair
– Immediate
– Cut drive controller
pulse disable
from power lines
– Return the amplifier
for repair
– Immediate
– Check the motor
locking of
cable connections
controller
– Acknowledge failure
– Immediate
– Check input voltage
locking of
supply
controller
– If the motor is used
as generator, reduce
the regenerating
power
– Acknowledge failure
9.1 Error Messages