DANGER
Jetter AG
Technical Data
Electrical Specification
Danger in the event that the Electrical Specification for the
"Safe Torque Off (STO)" option of the JM-2xx-xxx...-S1 amplifiers
is not complied with.
Serious injuries can occur!
For example from
•
electric shock because the electrical safety has been violated by not observing
the degree of pollution;
•
crushing if the functionality of the safety function STO is not ensured.
Make sure that the following electrical specifications are met.
Electrical Specification
Rated voltage supply
Type of power supply connection
Power supply tolerance
Inrush current limitation
5.1 Electrical Specification
•
Direct suuply U
= 230 V
eff
Common mode of the voltage 2 % max.
Voltage dips 10 ms max. at rated power
and rated voltage
•
48 ... 62 Hz
Frequency change 2 % / s max.
one-phase: direct (U
= 230 V: L to N)
eff
U
= 195 V ... 265 V(-15 % ... + 15 %)
eff
< 7 A limited to typ. 350 ms during the
switch-on-sequence
Refer to "Time between deactivating and
activating the mains power supply" on
page 41