Electrical Installation - Jetter JetMove D203 User Manual

Digital servoamplifier
Table of Contents

Advertisement

2 Installation of the JetMove D203
2.3
26

Electrical Installation

Check for correct motor and servo amplifier assignment.
Compare rated voltage and continuous rated current of servo amplifier
and motor.
The motor must be isolated against voltages of DC 500 V min.; please
also refer to "Compatible Synchronous Servo Motors" on page 43.
Connect the JetMoveD203 according to the connection wiring diagram
shown in chapter 10 "Connection Diagrams", page 87.
Especially check the power lines for appropriate protection, see
"Overload Protection" on page 38.
We do not recommend to fuse the motor cables.
Select the cables according to standards.
Verify that all earthing cables are connected (double earthing).
To connect resolvers or power units you can use prefabricated cables
available from Jetter or opt for self-made cables. Please refer to
chapter 7 "Description of Connections", page 49.
To ensure that installation is carried out in conformance with EMC
regulations, follow the instructions below:
– If possible, do not connect the controller cable together with the
power supply and motor cable;
– Connect the position transducer;
– Use shielded terminals or EMC-compliant connectors;
– Connect the holding brake, if available, and connect shields at both
ends of the cables;
– Connect the motor leads according to fig. 3, page 22.
Please also follow the instructions in chapter 1.4 "Instructions on EMC",
page 20.