Diagnostics; Fault Messages - Jetter JM-206-230 User Manual

Digital servo amplifier
Table of Contents

Advertisement

JetMove 206B-230
9
9.1
Error
Type of Error
Number
F 00
Hardware error
F 01
Internal voltage
supply error
F 02
Mains phase error
(is only active in
case of a 3-phase
connection)
F 03
Motor cable
breakage
F 04
Overvoltage in the
DC link
Jetter AG

Diagnostics

Fault Messages

Note!
In the case of a fault message, the letter "F" and two successive numbers appear
on the seven-segment display every second.
Fault Message Table JetMove 206B-230
Description
Internal hardware
defect
One or more power
supply voltages are
beyond their limits.
Failure of one of the
mains phases.
The motor cable is
broken.
Please be careful:
The motor cable is
tested when the
drive controller is
enabled for the first
time.
A DC link voltage of
> 480 V is detected.
Reaction
Remedy
– Immediate
– Separate the drive
motor power
controller from the
disable
power lines.
– Return the amplifier for
repair.
– Immediate
– Separate the drive
motor power
controller from the
disable
power lines.
– Return the amplifier for
repair.
– Immediate
– Check fuses and wiring.
motor power
– Acknowledge failure.
disable
– Immediate
– Check the motor cable
motor power
connections.
disable
– Acknowledge failure.
– Immediate
– Check input voltage
motor power
supply.
disable
– If the motor is used as
generator, reduce the
regenerating power.
– Acknowledge failure.
9.1 Fault Messages
73

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jm-206b-230

Table of Contents