Incremental Encoder Connection; Specifications - Jetter JetMove D203 User Manual

Digital servoamplifier
Table of Contents

Advertisement

7 Description of Connections
7.6
7.6.1
Specification of the connector for terminal X71 / X81 (ENCODER)
Specification of the incremental encoder cable
66

Incremental Encoder Connection

Specifications

15-pin male SUB-D connector
Metallized enclosure
Cable size: 3 * 2 * 0.14 mm² + 2 * 0.5 mm² min. (AWG 26(6) + AWG 20(2)), if the
wires of the thermal sensor have not been integrated in the encoder cable.
Cable size: Additionally 1 * 2 * 0.14 mm² min. (AWG 26(2)), if the wires of the
thermal sensor have been integrated in the encoder cable.
Cable size: Additionally 1 * 2 * 0.14 mm² min. (AWG 26(2)), if the sense wires
have been integrated in the encoder cable.
2 * 0.5 mm² (AWG 20(2)) has to be used for the power supply unit and for GND
Twisted-pair cables shielded with the all-over shield must be used; the signal lines
must also be twisted in pairs:
K0 + and referencing K0
K1 + and referencing K1
K2 + and referencing K2
0 V and voltage supply
The shield must be connected to the connector housings on both ends of the
cable with the greatest possible surface area.
Material: Copper
Temperature class: 60 °C
Maximum cable length: 100 m
Jetter AG

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jm-d203-230