7 Description of Connections
7.7
Specification of terminal X10
•
•
•
•
Specification of terminal X72 / X82
•
•
•
•
70
Digital Inputs, Logic Power Supply
2-pin screw clamping terminal (type MC 1.5/ 2-ST-3.5)
Cross-sectional area of connecting cable: 0.14 ... 1.5 mm
with bootlace ferrules in a plastic sleeve: 0.25 ... 0.5 mm
Bladed screw-driver: 0.4 x 2.5 mm
Stud torque for the screw clamping terminal: 0.22 Nm (1.95 lbf-inch)
Power Supply - Logic Circuit
Terminal
Signal
X10
DC 24 V
Power
supply
0 V
Common
ground
10-pin screw clamping terminal (type MC 1.5/ 10-ST-3.81)
Cross-sectional area of connecting cable: 0.14 ... 1.5 mm
with bootlace ferrules in a plastic sleeve: 0.25 ... 0.5 mm
Bladed screw-driver: 0.4 x 2.5 mm
Stud torque for the screw clamping terminal: 0.22 Nm (1.95 lbf-inch)
Digital Inputs, Brake Terminals
Terminals
Signal
X72/X82
DC 24 V
Sensor
OUT
supply
voltage
REF
Reference
switch
(Input)
0 V
Common
ground
Description
Power supply of the logic
unit
Ground for logic power
supply
Description
•
This voltage output can
be used for supplying
the reference and limit
switches.
•
Depending on the
parameter setting, this
input is used for
reference run
2
(AWG 26 ... AWG 16)
2
(AWG 24 ... AWG 20)
Specification
DC 20 ... 28.8 V
(I < 1.3 A)
2
(AWG 26 ... AWG 16)
2
(AWG 24 ... AWG 20)
Specification
DC 20 .. 28.8 V
(I < 100 mA)
•
DC 24 V
•
7.5 mA max.
•
Operating point:
< 6 V low,
> 15 V high
NC or NO contact
*)
Ground
for all
inputs
Jetter AG