7 Description of Connections
7.5
58
Digital Inputs, Logic Power Supply
Digital Inputs, Logic Power Supply
Wiring
Signal
terminal X10
at the
amplifier
ENABLE
Hardware
enable for
the power
supply of the
motor
(Input)
REF
Reference
switch
(Input)
LIMIT +
Positive limit
switch (input)
LIMIT -
Negative
limit switch
(input)
INPUT
Digital Input
Function
•
At this input, a high
signal is necessary for
power supply of the
motor. (This signal must
have been applied
before carrying out the
software enable)
•
A low signal de-
energizes the motor
immediately.
•
Depending on the
parameter setting, this
input is used for
reference run
•
Depending on the
parameter setting, this
input is used as a
positive limit switch.
•
Depending on the
parameter setting, this
input is used as a
negative limit switch.
•
Depending on the
parameter setting, this
input can be used for
quick stop, position
capture or referencing
without stop.
JetWeb
Specification
•
DC 24 V
•
7.5 mA max.
•
Operating point:
< 6 V low,
> 15 V high
•
DC 24 V
•
7.5 mA max.
•
Operating point:
< 6 V low,
> 15 V high
NC or NO contact
•
DC 24 V
•
7.5 mA max.
•
Operating point:
< 6 V low,
> 15 V high
NC or NO contact
•
DC 24 V
•
7.5 mA max.
•
Operating point:
< 6 V low,
> 15 V high
NC or NO contact
•
DC 24 V
•
7.5 mA max.
•
Operating point:
< 6 V low,
> 15 V high
Jetter AG