Technical Data; Electrical Specifications - Jetter JM-206-230 User Manual

Digital servo amplifier
Table of Contents

Advertisement

JetMove 206B-230
5
5.1
Jetter AG

Technical Data

Electrical Specifications

Electrical Specifications
Rated voltage supply
Power supply connection
for a rated power of the motor,>
1kW, a three-phase connection
is standard.
Power supply tolerance
Inrush current limitation
Overload protection
Output voltage of the motor
Motor output current at an ambient
temperature of 45 °C
5.1 Electrical Specifications
Direct supply U
= 230 V
eff
Common mode voltage 2 % max.
Power dissipation 3 ms max.
48 ... 62 Hz
Frequency change max. 2 %/s
1-phase: direct (U
eff
3-phase: via autotransformer or isolating
transformer
e.g.
Primary circuit:
U
Secondary circuit: U
See "Note 1!" on page 39.
U
= 195 V ... 265 V (-15 % ... + 15 %)
eff
< 30 A limited to 50 ms during the switch-on-
sequence
Refer to "Time between deactivating and
activating the mains power supply" on
page 40
For each phase an external overload
protection is required, for example
– circuit breaker 10 A C
– fuse 10 A M (medium time lag)
– motor circuit breaker 10 A
For systems with UL approval, use overload
protection devices that are UL listed (acc. to
UL 508) (HKJH) and a self-protected
combination motor controller (specification:
230 V, 10 A) for UL-certified systems. The
JetMove 206B-230 is suitable for use on a
circuit capable of delivering not more than
50,000 rms symmetrical Ampere, 600 Volt
max.
eff
Three-phase with 325 V typical (480 V
max.)
Nominal current: I
= 6 A
eff
Spitzenstrom min. 5 Sekunden: I
(The duration depends on the temperature
of the heat sink)
See "Note 2!" on page 39.
= 230 V: L to N)
= 3 x 400 V.
eff
= 3 x 230 V
eff
= 12 A
eff
37