Complete Manual for RoboSHOT 12E NDI and RoboSHOT 30E NDI High-Performance PTZ Cameras
Basic Camera Settings
S
, DIP S
YSTEM PAGE
WITCHES TAB
Standard Control Mode/Codec Control Mode – Select Codec Control Mode if using the camera with a
third-party codec.
IR1, IR2, IR3 (Frequency Selection): If there are two or three cameras in the room, they can be set to
respond to different IR frequencies so that you can control each one independently using the IR Remote
Commander. Use these two switches to configure the camera for the desired IR frequency. Then use the
Camera Select buttons at the top of the remote to select the camera you want to control.
Left and right IR switches up: IR frequency 1
n
Left IR switch down, right IR switch up: IR frequency 2
n
Left IR switch up, right IR switch down: IR frequency 3
n
IR On/Off: Leave this switch ON if the IR Remote Commander will be used.
Image Flip: If using an inverted mounting solution, set the Image Flip switch ON. This orients the video
image correctly and sets the tilt motors to respond appropriately to tilt up and down commands from the
remote, web interface, and connected control devices.
Baud Rate: Set this switch to match the baud rate of the device connected to the RS-232 port.
HDMI color: YCbCr (default) or sRGB.
38