Rs-232 Serial Communication Settings; Rs-232 Connector Pin-Out - LEGRAND vaddio RoboSHOT 12E NDI Complete Manual

High-performance ptz cameras
Table of Contents

Advertisement

Complete Manual for RoboSHOT 12E NDI and RoboSHOT 30E NDI High-Performance PTZ Cameras

RS-232 Serial Communication Settings

In most situations, all control is via the NDI connection; however, the RS-232 serial port (color-coded blue)
provides an alternate means of controlling the camera from a third-party device. If using the RS-232
connection, be sure the camera is set to the same baud rate as the external control device.
Specification
Communication Speed
Number of start bits
Number of stop bits
Number of data bits
Parity
Flow control
The camera's default baud rate is 9600. The 38400 baud setting is optional if the connected device
supports it.

RS-232 Connector Pin-Out

Pin 1: Not used
n
Pin 2: Not used
n
Pin 3: Not used
n
Pin 4: Not used
n
Pin 5: Not used
n
Pin 6: GND
n
Pin 7: RXD (from TXD of control source)
n
Pin 8: TXD (to RXD of control source)
n
Caution
Check your cables. Connecting a cable to the wrong port or using the wrong pin-out can result in equipment
damage and will void the warranty.
Value
9600 or 38400 baud, selectable
1
1
8
None
None
8