6 PROGRAMMING
6 - 24
(2) Operating the utility package
(a) Initial setting (refer to Section 5.4)
<When cascade control is not executed>
CH1 Input range ......................................................."0"
CH2 Unused channel setting ..................................."Not Used"
[Limiter setting]
CH1 Upper setting limiter ........................................."2000"
CH1 Lower setting limiter ........................................."0"
[Alert function setting]
CH1 Alert 1 mode setting ........................................."UprLmt Input"
CH1 Alert set value 1................................................"1800"
[Normal control setting]
CH1 Set value (SV) setting ......................................"800"
[Program control setting]
CH1 Execution pattern ............................................."Program Pattern 1"
CH1 Time scale ........................................................"1s"
CH1 Program pattern 1
Final segment..................................................."4"
Segment 1 Set value (SV) setting ..................."1500"
Segment 1 Executing time..............................."200"
Segment 1 Zone PID data No. ........................"2"
Segment 2 Set value (SV) setting ..................."1500"
Segment 2 Executing time..............................."100"
Segment 2 Zone PID data No. ......................."2"
Segment 3 Set value (SV) setting ..................."500"
Segment 3 Executing time..............................."100"
Segment 3 Zone PID data No. ........................"1"
Segment 4 Set value (SV) setting ..................."500"
Segment 4 Executing time..............................."100"
Segment 4 Zone PID data No. ......................."1"
<When cascade control is executed>
CH1 Input range ......................................................."0"
CH2 Input range ......................................................."0"
CH1 Unused channel setting ..................................."Used"
CH2 Unused channel setting ..................................."Used"
[Limiter setting]
CH1 Upper setting limiter ........................................."2000"
CH1 Lower setting limiter ........................................."0"
CH2 Upper setting limiter ........................................."2000"
CH2 Lower setting limiter ........................................."0"
[Normal control setting]
CH1 Set value (SV) setting ......................................"1000"
MELSEC-Q
6 - 24