3 SPECIFICATIONS
Address
(decimal (hexadecimal))
CH1
CH2
45 (2D
)
77 (4D
)
Sensor compensation value setting
H
H
46 (2E
)
78 (4E
)
AT differential gap
H
H
47 (2F
)
79 (4F
)
AT additional lag
H
H
48 (30
)
80 (50
)
Primary delay digital filter setting
H
H
49 (31
)
81 (51
)
Control response parameter
H
H
50 (32
)
82 (52
)
Control mode
H
H
51 (33
)
83 (53
)
MAN output setting
H
H
52 (34
)
84 (54
)
Setting change rate limiter
H
H
AT bias
53 (35
)
85 (55
)
H
H
Forward/reverse action setting
54 (36
)
86 (56
)
H
H
Upper setting limiter
55 (37
)
87 (57
)
H
H
Lower setting limiter
56 (38
)
88 (58
)
H
H
Program control run/reset
57 (39
)
89 (59
)
H
H
Loop disconnection detection
59 (3B
)
91 (5B
)
H
H
judgement time
Loop disconnection detection dead
60 (3C
)
92 (5C
)
H
H
band
Unused channel setting
61 (3D
)
93 (5D
)
H
H
PID constant read command from
62 (3E
)
94 (5E
)
H
H
FeRAM
Automatic backup setting after auto
63 (3F
)
95 (5F
)
H
H
tuning of PID constants
164 (A4
)
Alert dead band setting
H
165 (A5
)
Alert delay count
H
3 - 66
Item
*1: Reading data is always available regardless of the write conditions. The setting value of the item to
which "Setting mode" is given as the condition for writing data can be changed only in the setting mode.
Note that changing the value in the operation mode causes a write data error. In addition, it is necessary
to turn on Setting change command (YnB) to change the setting value.
Range
-5000 to 5000
(
0.1 ,
0.01%)
0 to 10000 (
0.01s)
0 to 1000 (
0.01s)
0 to 1000 (
0.1s)
0: Slow, 1: Normal, 2: Fast
0: Normal control
1: Manual control 1
2: Program control
3: Manual control 2
Manual
-50 to 1050
control 1
(
0.1%)
Manual
0 to 4000
control 2
Thermocouples
1 to 10000
( )
(
0.1 /min)
Micro voltage
(mV), voltage (V),
0 to 1000
current input
(
0.1%/min)
(mA)
full-scale
0: Forward action, 1: Reverse
action
Input range
0: RESET, 1: RUN
0 to 7200 (s)
0 to full-scale
0: Used, 1: Unused
0: Without, 1: With command
0: OFF, 1: ON
Thermocouples
0 to 1000
( )
(
0.1 )
Micro voltage
(mV), voltage (V),
0 to 1000
current input
(
0.01%)
(mA)
0 to 255
MELSEC-Q
(From the previous page)
Write condition
*1
Default
Setting
Always
Disabled
mode
0
10
10
0
0
0
-50
0
0
1
13720
-2000
0
80
0
0
0
0
5
0
(To the next page)
Reference
Section
3.5.18
Section
3.5.19
Section
3.5.20
Section
3.5.21
Section
3.5.22
Section
3.5.23
Section
3.5.24
Section
3.5.25
Section
3.5.26
Section
3.5.27
Section
3.5.28
Section
3.5.29
Section
3.5.30
Section
3.5.31
Section
3.5.32
Section
3.5.33
Section
3.5.34
Section
3.5.35
Section
3.5.36
3 - 66