Mitsubishi Electric MELSEC-Q Series User Manual page 103

Loop control module
Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

3 SPECIFICATIONS
Address
(decimal (hexadecimal))
CH1
CH2
261 (105
)
517 (205
)
Wait status flag
H
H
262 (106
)
518 (206
)
Hold status flag
H
H
263 (107
)
519 (207
)
Advancing completion flag
H
H
264 (108
)
520 (208
)
Execution pattern monitor
H
H
265 (109
)
521 (209
)
Zone PID monitor
H
H
266 (10A
) 522 (20A
)
Forced output status flag
H
H
272 (110
)
528 (210
)
Execution pattern
H
H
273 (111
)
529 (211
)
Start mode
H
H
274 (112
)
530 (212
)
Time scale
H
H
275 (113
)
531 (213
)
Zone 1 upper limit
H
H
276 (114
)
532 (214
)
Zone 2 upper limit
H
H
277 (115
)
533 (215
)
Zone 3 upper limit
H
H
278 (116
)
534 (216
)
Zone 4 upper limit
H
H
279 (117
)
535 (217
)
Zone 5 upper limit
H
H
280 (118
)
536 (218
)
Zone 6 upper limit
H
H
281 (119
)
537 (219
)
Zone 7 upper limit
H
H
282 (11A
) 538 (21A
)
H
H
Zone 1
283 (11B
) 539 (21B
)
H
H
284 (11C
) 540 (21C
)
H
H
285 (11D
) 541 (21D
)
H
H
286 (11E
) 542 (21E
)
H
H
Zone 2
287 (11F
) 543 (21F
)
H
H
288 (120
)
544 (220
)
H
H
289 (121
)
545 (221
)
H
H
3 - 68
Item
0: Forced output not commanded
1: With forced output command
1 to 3
0: Zero start
1: PV start 1 (time fixed)
2: PV start 2 (time shortened)
3: PV start 3 (time shortened/find
type)
4: SV start
0: 0.01s, 1: 0.1s,
2: 1s, 3: 1min
Input range lower limit to Zone 2
upper limit
Zone 1 upper limit to Zone 3
upper limit
Zone 2 upper limit to Zone 4
upper limit
Zone 3 upper limit to Zone 5
upper limit
Zone 4 upper limit to Zone 6
upper limit
Zone 5 upper limit to Zone 7
upper limit
Zone 6 upper limit to Input range
upper limit
Thermocouple
( )
Proportional band (P)
Micro voltage
setting
(mV), voltage
(V), current (mA)
Integral time (I)
0 to 32767 (
Derivative time (D)
0 to 32767 (
Control response
0: Slow, 1: Normal, 2: Fast
parameter
Thermocouple
( )
Proportional band (P)
Micro voltage
setting
(mV), voltage
(V), current (mA)
Integral time (I)
0 to 32767 (
Derivative time (D)
0 to 32767 (
Control response
0: Slow, 1: Normal, 2: Fast
parameter
*1: Reading data is always available regardless of the write conditions. The setting value of the item to
which "Setting mode" is given as the condition for writing data can be changed only in the setting mode.
Note that changing the value in the operation mode causes a write data error. In addition, it is necessary
to turn on Setting change command (YnB) to change the setting value.
Range
Default
1
0
0
Input range
upper limit
Input range
upper limit
Input range
upper limit
Input range
upper limit
Input range
upper limit
Input range
upper limit
Input range
upper limit
1 to full-scale
(
0.1 )
100
1 to 10000
(
0.1%)
0.1s)
400
0.1s)
100
0
1 to full-scale
(
0.1 )
100
1 to 10000
(
0.1%)
0.1s)
400
0.1s)
100
0
MELSEC-Q
(From the previous page)
Write condition
*1
Setting
Reference
Always
Disabled
mode
(To the next page)
3 - 68
Section
3.5.58
Section
3.5.59
Section
3.5.60
Section
3.5.61
Section
3.5.62
Section
3.5.63
Section
3.5.64
Section
3.5.65
Section
3.5.66
Section
3.5.67