Mitsubishi Electric MELSEC-Q Series User Manual page 109

Loop control module
Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

3 SPECIFICATIONS
Address
(decimal (hexadecimal))
CH1
CH2
448 (1C0
) 704 (2C0
)
H
H
449 (1C1
) 705 (2C1
)
H
H
450 (1C2
) 706 (2C2
)
H
H
451 (1C3
) 707 (2C3
)
H
H
452 (1C4
) 708 (2C4
)
H
H
453 (1C5
) 709 (2C5
)
H
H
454 (1C6
) 710 (2C6
)
H
H
455 (1C7
) 711 (2C7
)
H
H
456 (1C8
) 712 (2C8
)
H
H
457 (1C9
) 713 (2C9
)
H
H
458 (1CA
) 714 (2CA
)
H
H
459 (1CB
) 715 (2CB
)
H
H
460 (1CC
) 716 (2CC
)
H
H
461 (1CD
) 717 (2CD
)
H
H
462 (1CE
) 718 (2CE
)
H
H
463 (1CF
) 719 (2CF
)
H
H
464 (1D0
) 720 (2D0
)
H
H
465 (1D1
) 721 (2D1
)
H
H
466 (1D2
) 722 (2D2
)
H
H
467 (1D3
) 723 (2D3
)
H
H
468 (1D4
) 724 (2D4
)
H
H
469 (1D5
) 725 (2D5
)
H
H
470 (1D6
) 726 (2D6
)
H
H
471 (1D7
) 727 (2D7
)
H
H
472 (1D8
) 728 (2D8
)
H
H
473 (1D9
) 729 (2D9
)
H
H
3 - 74
Item
Final segment
Pattern link
Iteration
Output time of pattern end
Wait zone setting
Set value(SV)
setting
Executing
Segment 1
time
Zone PID
data No.
Set value(SV)
setting
Executing
Segment 2
time
Zone PID
data No.
Set value(SV)
setting
Executing
Segment 3
time
Zone PID
data No.
Set value(SV)
setting
Executing
Segment 4
time
Zone PID
data No.
Set value(SV)
setting
Executing
Segment 5
time
Zone PID
data No.
Set value(SV)
setting
Executing
Segment 6
time
Zone PID
data No.
Set value(SV)
setting
Executing
Segment 7
time
Zone PID
data No.
*1: Reading data is always available regardless of the write conditions. The setting value of the item to
which "Setting mode" is given as the condition for writing data can be changed only in the setting mode.
Note that changing the value in the operation mode causes a write data error. In addition, it is
necessary to turn on Setting change command (YnB) to change the setting value.
Range
1 to 16
0 to 3 (0: No link)
1 to 999 times, 1000: Endless
0 to 30000 (
0.01s,
0.1s,
1s,
1min)
0 to full-scale
Input range
0 to 30000 (
0.01s,
0.1s,
1s,
1min)
0 to 8 (0: Specifies zones including
current set value)
Input range
0 to 30000 (
0.01s,
0.1s,
1s,
1min)
0 to 8 (0: Specifies zones including
current set value)
Input range
0 to 30000 (
0.01s,
0.1s,
1s,
1min)
0 to 8 (0: Specifies zones including
current set value)
Input range
0 to 30000 (
0.01s,
0.1s,
1s,
1min)
0 to 8 (0: Specifies zones including
current set value)
Input range
0 to 30000 (
0.01s,
0.1s,
1s,
1min)
0 to 8 (0: Specifies zones including
current set value)
Input range
0 to 30000 (
0.01s,
0.1s,
1s,
1min)
0 to 8 (0: Specifies zones including
current set value)
Input range
0 to 30000 (
0.01s,
0.1s,
1s,
1min)
0 to 8 (0: Specifies zones including
current set value)
MELSEC-Q
(From the previous page)
Write condition
*1
Default
Setting
Always
Disabled
mode
16
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
(To the next page)
Reference
Section
3.5.68
3 - 74